WorthRand Products

Overhung Pumps

Mark 3 ASME Standard
Mark 3 ASME Standard

Standards • ASME (ANSI) B73.1 Operating Parameters • Flows to 4540 m3/h (20 000 gpm) • Heads to 215 m (700 ft) • Pressures to 27 bar (400 psi) • Temperatures from -73°C (-100°F) to 370°C (700°F) Features • Exclusive reverse vane impeller • Standard Mark 3A power end – External micrometer impeller adjustment – Double row angular contact outboard bearings and single row, deep groove inboard bearings – Double lip oil seals – Constant level oiler

press to zoom
Mark 3 Unitized Self Primer
Mark 3 Unitized Self Primer

Standards • Flowserve Operating Parameters • Flows to 320 m3/h (1400 gpm) • Heads to 120 m (400 ft) • Pressures to 20 bar (285 psi) • Temperatures to 370°C (700°F) • Static suction lift to 6 m (20 ft) Features • Unitized casing with large priming chamber, air separator and volute • Exclusive reverse vane impeller standard; open impeller optional

press to zoom
Mark 3 Recessed
Mark 3 Recessed

Standards • Flowserve Operating Parameters • Flows to 455 m3/h (2000 gpm) • Heads to 120 m (400 ft) • Pressures to 20 bar (285 psi) • Temperatures from -73°C (-100°F) to 370°C (700°F) Features • Low shear vortex pumping action • Fractional media contact with the impeller • Standard CD4MCuN impeller • Thick-wall wet end components suitable for light slurries • Standard Mark 3A power end

press to zoom
Mark 3 In-Line
Mark 3 In-Line

Standards • ASME (ANSI) B73.2 Operating Parameters • Flows to 370 m3/h (1630 gpm) • Heads to 230 m (755 ft) • Pressures to 24 bar (350 psi) • Temperatures from -73°C (-100°F) to 370°C (700°F) Features • Exclusive reverse vane impeller • Standard Mark 3A power end

press to zoom
Guardian Magnetic Drive
Guardian Magnetic Drive

Standards • ASME (ANSI) B73.1 dimensions Operating Parameters • Flows to 375 m3/h (1650 gpm) • Heads to 215 m (700 ft) • Pressures to 24 bar (350 psi) • Temperatures from -73°C (-100°F) to 290°C (550°F) Features • Magnetic drive design • Alloy C-276 containment shell • Rare earth magnets • Low NPSHR, reverse vane impeller • Casings and impellers interchangeable with sealed configuration

press to zoom
Mark 3 ISO Self-Priming
Mark 3 ISO Self-Priming

Standards • ISO 2858 • ISO 5199 Operating Parameters • Flows to 100 m3/h (440 gpm) • Heads to 100 m (330 ft) • Pressures to 25 bar (365 psi) • Temperatures from -80°C (-110°F) to 350°C (660°F) Features • One-piece casing with integral priming chamber, air separator and volute • Reflux priming principle eliminates need for internal valves and external priming devices • High-efficiency, low NPHSR, precision cast, semi-open impeller • Run-dry capability • SealSentry seal chambers

press to zoom
Mark 3 ISO Recessed
Mark 3 ISO Recessed

Standards • ISO 2858 • ISO 5199 Operating Parameters • Flows to 750 m3/h (3300 gpm) • Heads to 100 m (330 ft) • Pressures to 25 bar (365 psi) • Temperatures from -80°C (-110°F) to 350°C (660°F) Features • Heavy-duty casing with integral foot and multi-ribbed discharge flange • Vortex action minimizes abrasive wear and maintains solids integrity • Standard high-efficiency, semi-open impeller precision cast in CD4MCuN duplex stainless steel • SealSentry seal chambers • Accepts multiple seal arrang

press to zoom
Mark 3 ISO Standard
Mark 3 ISO Standard

Standards • ISO 2858 • ISO 5199 Operating Parameters • Flows to 1400 m3/h (6160 gpm) • Heads to 220 m (720 ft) • Pressures to 25 bar (365 psi) • Temperatures from -80°C (-110°F) to 350°C (660°F) • 40 sizes with discharges from 20 mm (0.75 in) to 200 mm (8 in) Features • Heavy-duty casing with integral foot and multi-ribbed discharge flange • Reverse vane impeller standard; open impeller available • SealSentry seal chambers • Accepts multiple seal arrangements • External micrometer impeller adjus

press to zoom
CPXV Chemical Sump
CPXV Chemical Sump

• ISO 13709/API 610, 8th & 10th ed. • ISO 5199 Operating Parameters • Flows to 1400 m3/h (6160 gpm) • Heads to 250 m (820 ft) • Pressures to 25 bar (365 psi) • Temperatures from -40°C (-40°F) to 350°C (660°F) Features • Heavy-duty casing with multi-ribbed discharge flange • High-efficiency, semi-open impeller • Column lengths to 10 m (32 ft) • Heavy-duty thrust bearings with axial adjustment above soleplate level • Accepts multiple seal arrangements • Elastomeric split element coupling

press to zoom

Between Bearing Pumps

LR Axially Split, Single-Stage
LR Axially Split, Single-Stage

Standards • Flowserve Operating Parameters • Flows to 2000 m3/h (8800 gpm) • Heads to 170 m (560 ft) • Pressures to 21 bar (300 psi) • Temperatures from -30°C (-20°F) to 150°C (300°F) Features • Split case design with lifting lugs • Low NPSH double-suction impeller on many sizes • Flat or raised face suction and discharge flanges to ANSI, DIN and ISO standards • Oil or grease lubricated radial and thrust bearings – Single row, deep groove ball bearings or duplex thrust ball bearings

press to zoom
LPN BB1 Axially Split Double Suction
LPN BB1 Axially Split Double Suction

Standards • ISO 13709/API 610 (BB1), latest ed. Operating Parameters • Flows to 15 000 m3/h (65 000 gpm) • Heads to 250 m (820 ft) • Pressures to 25 bar (365 psi); 50 bar (725 psi) with LPN-H model • Temperatures from -80°C (-110°F) to 150°C (300°F) Features • Double volute, near-centerline supported casing • ASME (ANSI) B16.5 Class 150 or Class 300 raised face flanges • Confined gasket design • Hydraulically balanced doublesuction impeller • ISO 21049/API 682 seal chambers

press to zoom
LNN Axially Split, Double- Suction
LNN Axially Split, Double- Suction

Standards • Flowserve Operating Parameters • Flows to 30 000 m3/h (132 000 gpm) • Heads to 300 m (980 ft) • Pressures to 40 bar (580 psi) • Temperatures to 140°C (285°F) Features • Heavy-duty, double volute casing with side suction and side discharge • Flanges to ANSI, DIN and ISO standards • Hydraulically balanced doublesuction impeller • Optimum axial and radial thrust balance • Standard casing wear rings; optional impeller wear rings

press to zoom
DVSH BB1 Axially Split
DVSH BB1 Axially Split

Standards • ISO 13709/API 610 (BB1), latest ed. Operating Parameters • Flows to 12 000 m3/h (52 835 gpm) • Heads to 565 m (1854 ft) • Pressures to 150 bar (2175 psi) • Temperatures to 200°C (400°F) • Speeds to 6000 rpm Features • Double volute casing • Hydraulically balanced doublesuction impeller • ISO 21049/API 682 seal chambers accommodates multiple seal types • Stiff shaft design • Baseplate designs and pump packages engineered to contract requirements

press to zoom
DMX (BB3) Axially Split, Multistage
DMX (BB3) Axially Split, Multistage

Standards • ISO 13709/API 610 (BB1), latest ed. Operating Parameters • Flows to 2950 m3/h (13 000 gpm) • Heads to 2130 m (7000 ft) • Pressures to 275 bar (4000 psi) • Temperatures to 200°C (400°F) • Speeds to 6000 rpm Features • Double volute hydraulic passages • Renewable case and impeller wear rings • ISO 21049/API 682 seal chambers • Axially split center bushing • Shaft options – Double extension for connection to auxiliary pumps or hydraulic turbines

press to zoom
EC Axially Split, Multistage
EC Axially Split, Multistage

Standards • Flowserve Operating Parameters • Flows to 2340 m3/h (10 300 gpm) • Heads to 650 m (2130 ft) • Pressures to 88 bar (1300 psi) • Temperatures from -30°C (-20°F) to 150°C (300°F) Features • Horizontally split case with integral mounting feet • In-line mounted impellers • Rotating assembly balanced as a unit • Case wear rings standard at impeller eye • Diaphragm rings standard at impeller back shroud • Shaft protected by interstage sleeves and packing sleeves • Seal chambers accommodate

press to zoom
UZDL (BB1) Axially Split, Two-Stage
UZDL (BB1) Axially Split, Two-Stage

Standards • ISO 13709/API 610 (BB1), latest ed. Operating Parameters • Flows to 2950 m3/h (13 000 gpm) • Heads to 685 m (2250 ft) • Pressures to 64 bar (910 psi) • Temperatures to 200°C (400°F) • Speeds to 2000 rpm Features • Double volute hydraulic passages • ISO 21049/API 682 seal chambers • Shaft options – Double extension for connection to auxiliary pumps or hydraulic turbines – Special shaft end machining for hydraulic fitted couplings

press to zoom
HDX-TT (BB2) Recovery Turbine
HDX-TT (BB2) Recovery Turbine

Standards • ISO 13709/API 610 (BB2), latest ed. Operating Parameters • Flows to 4100 m3/h (18 000 gpm) • Heads to 760 m (2500 ft) • Pressures to 100 bar (1450 psi) • Temperatures to 450°C (850°F) Features • Double volute, centerline supported, self-venting casing with diffuser • ASME (ANSI) B16.5 Class 300 flanges; optional Class 600 and 900 flanges • Dynamically balanced, doublesuction, radial inflow turbine runner • Stiff shaft design • ISO 21049/API 682 seal chambers

press to zoom
HDX (BB2) Double Suction
HDX (BB2) Double Suction

Standards • ISO 13709/API 610 (BB2), latest ed. Operating Parameters • Flows to 4100 m3/h (18 000 gpm) • Heads to 450 m (1500 ft) • Pressures to 42 bar (610 psi); 100 bar (1450 psi) with HDX-H model • Temperatures to 450°C (850°F) Features • Double volute, centerline supported, self-venting casing • ASME (ANSI) B16.5 Class 300 flanges; optional Class 600 and 900 flanges • Dynamically balanced, doublesuction impeller • Stiff shaft design • ISO 21049/API 682 seal chambers

press to zoom